FLK787 | FLUKE 787 PROCESS METER

SKU: FLK787

Availability:

1 in stock


Kindly be advised that although this item is brand new and unused, it is older stock and is the last remaining unit available, hence the heavily discounted price. The accompanying photos depict the actual product.

1 in stock

Quantity Price Per Unit
1+ $1,089.00 Incl GST $990.00 Excl GST

A maintenance and calibration tool that will be at home in every instrumentation technician’s tool box, the Fluke 787 ProcessMeterâ„¢ combines a DMM and a Loop Calibrator in one rugged, handheld tool, for about what you would expect to pay for a loop calibrator alone. Based on the trusted Fluke 87 DMM, the 787 adds the ability to measure, source, and simulate dc loop current with 0.05% accuracy and 1 microamp resolution.

  • DMM and loop calibrator in one tool
  • Clear LCD with backlight; 4,000 counts (30,000 counts for DC current)
  • Externally accessible battery for easy battery changes.
  • 1000 V overload protection on V, ohms, frequency.
  • 150 V overload protection on mA, backed up by 440 mA 1000V fuse.
  • 25% Manual Step plus Auto Step and Auto Ramp on mA output.

Fluke combined the DMM you trust with the loop calibrator you need.

The Fluke 787 ProcessMeterâ„¢ puts a complete troubleshooting solution in the palm of your hand. Get in touch with more information, faster and easier with the newest member of the Fluke 80 Series, the 787 ProcessMeter. The 787 gives you the measurement capabilities you expect from our rugged, reliable DMMs plus the ability to source, simulate, or measure dc current with 1 microamp resolution and accuracy of 0.05%. Put it all together and you have the ideal tool for troubleshooting and calibrating current loop applications. So if you’re tired of always tracking down a calibrator, lugging around two tools and switching back and forth, get the single best solution for doubling your power. The 787 ProcessMeter from Fluke.

Precision 1000 V, 440 mA digital multimeter

  • Measure AC and DC volts, AC and DC current, resistance, continuity, and frequency
  • 0.1% DC voltage accuracy
  • 0.05% DC current accuracy, 1 ‘A resolution to 30 mA
  • Simultaneous mA and % of scale readout
  • True rms AC voltage measurement to 1 kHz
  • Frequency measurement to 20 kHz
  • Min/Max/Average/TouchHold/Relative modes
  • Diode test and continuity beeper

DC current source/loop calibrator

  • 20 mA current source/simulator
  • Simultaneous mA and % of scale readout
  • Manual step (25%, coarse, fine) plus auto step and auto ramp
Current measurement Range 0-1 A
Resolution 1 mA
Accuracy 0.2% + 2 LSD
Range 0-30 mA
Resolution 0.001 mA
Accuracy 0.05% + 2 LSD
Current sourcing Range 0-20 mA or 4-20 mA
Resolution 0.05% of span
Drive Capability 500 Ω @ 24 mA
Frequency To 19.999 kHz, 0.005% + 1 LSD
Continuity Beeps for resistance < 100 ohms
Voltage measurement Range 0-1000 V AC or DC
Resolution 0.1 mV to 1.0 V
Accuracy 0.1% Rdg + 1 LSD (VDC)
Resistance measurement To 40 MΩ, 0.2% + 1 LSD
Diode test 2.4 V shows diode voltage drop
Environmental Specifications
Operating temperature -20°C to 55°C
Storage temperature -40°C to 60°C
Humidity (without condensation) 95% up to 30°C
75% up to 40°C
45% up to 50°C
35% up to 55°C
Temperature coefficient 0.05 x (specified accuracy) per °C (for temperatures < 18°C or > 28°C)
Safety Specifications
Electrical safety Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No. 1010.1-92
Overvoltage category IEC 1010-1 CAT III
Maximum voltage 1000 V rms
Mechanical and General Specifications
Size 32 x 87 x 187 mm
Weight 369 g
Batteries Single 9 V Alkaline battery (ANSI/NEDA 1604A or IEC 6LR61)
Warranty 3 years
Battery life 50 hours typical (measurement), 12 hours typical (sourcing 12 mA)
Shock and vibration Random, 2 g, 5-500 Hz
1 meter drop test
Display current and % of span Yes
Auto step, auto ramp Yes
Facebook